| Availability: | |
|---|---|
| Quantity: | |
Use Environmental Conditions
1. Altitude above sea level should not exceed 2000M.
2. Ambient air temperature: -5℃ ~+40℃ and the average temperature should not exceed +35℃ in 24h.
3. Air condition: With clean air. Relative humidity should not exceed 50% at +40℃ .Higher relative humidity is allowed at lower temperature. Ex. 90% at +20℃ .
4. Places without fire, explosive danger, serious pollution, chemical corrosion and fierce vibration.
5. Installation gradient not exceed 5° .
6. Control center is suitable to the transportation and store with following temperature: -25℃ ~+55℃ ,in short time (within 24h) it should not exceed +70℃ .
- Fully Sealed
- 20-Year Maintenance-Free
- Extreme Environment Resistant
- Five-Prevention Safety
- Universal Scenario Fit
| Project | C Module | F Module | V Module | CB Module | ||||
| Load switch | Combination appliance | Vacuum Switch | Isolation/grounding switch | Vacuum Circuit Breaker | Isolation/grounding switch | |||
| Rated voltage kV | 24 | 24 | 24 | 24 | 24 | 24 | ||
| Rated frequency Hz | 50 | 50 | 50 | 50 | 50 | 50 | ||
| Power frequency withstand voltage (phase/port) kV | 42/48 | 42/48 | 42/48 | 42/48 | 42/48 | 42/48 | ||
| Lightning impulse withstand voltage kV | 75/85 | 75/85 | 75/85 | 75/85 | 75/85 | 75/85 | ||
| Rated current A | 630 | Pour | 630 | 1250/630 | ||||
| Rated closed-loop breaking current A | 630 | |||||||
| Rated cable charging breaking current A | 135/135 | |||||||
| Rated short-circuit closing current (peak) | 50 | 80 | ||||||
| Rated peak withstand current kA | 50 | |||||||
| Rated short-time withstand current kA/3s | 20 | |||||||
| Rated short-circuit breaking current kA | 31.5 | 20 | 25 | 25 | ||||
| Rated transfer current A | 1750 | |||||||
| Equipped with fuse, maximum current A | - | 125 | ||||||
| Circuit resistance Ω | ≤300 | ≤600 | ||||||
| Mechanical lifespan (times) | 5000 | 3000 | 5000 | 2000 | 5000 | 5000 | ||
1. Commercial Complexes & High-Rise Residential
Modern commercial complexes and high-rise residential buildings require reliable, compact, and fire-safe power distribution equipment.
2. Industrial Parks & Heavy Manufacturing
Industrial parks and heavy manufacturing facilities, including steel mills, cement plants, chemical factories, and automotive assembly lines, consume large volumes of medium-voltage power and require robust, outdoor-rated distribution equipment.
3. PV & Energy Storage Grid Connection
Solar photovoltaic farms and battery energy storage systems (BESS) require dedicated step-up transformer solutions to interface with the medium-voltage grid.
4. Infrastructure — Rail Transit, Healthcare & Data Centers
Critical infrastructure applications, including metro and railway systems, hospitals, and data centers, demand the highest levels of power reliability and redundancy.
5. Municipal & Environmental — Water Treatment & Pumping Stations
Municipal water supply, wastewater treatment plants, and flood control pumping stations present challenging operating conditions for electrical distribution equipment.
Q:Are you a trading company or factory?
A:We are a manufacturer boasting 15 years of industry experience and holding proprietary import-export rights.
Q:What certifications do you have?
A:Yes, we hold ISO, CE, and IEC certificates. In addition, we possess a number of design patents and a Special Equipment Manufacturing License.
Q:How long is your delivery time?
A:For normal products in 7-10 days; For bulk order, in 15-25 days. It depends.
Q:What is the warranty time?
A:3 years warranty for all of our stainless steel products. Gaskets or the easy broken parts are not included due to the different application for customers.